Clinical medicine
ANALYSIS OF ACCURACY OF DETERMINING THE CENTRIC RELATION OF JAWS IN SECONDARY COMPLETE ADENTIA
Published
2024-10-16
Authors:
YB
Y.I. Bayramov
- Abstract:
-
The purpose of the study is to investigate the accuracy of determining jaw center relations in clinical practice in secondary complete adentia. In the study, complete removable plate prosthesis preparation was performed using the improved method in 204 patients aged 45 to 90 years, including 102 (50.0 %) men and 102 (50.0 %) women with secondary complete dentition, which constituted the main group. We performed traditional preparation of prosthesis in 405 patients aged 45 to 90 years, including 206 (50.9 %) men and 199 (49.1 %) women with second complete adenia, and formed a control group. The occlusal method was used to study the central jaw relationships in the central occlusal state. This method was compared with control group, when during preparing completely removed plate prosthesis, the area of the prosthesis and surrounding tissues are changed as a result of pressure when the doctor measures.
- Keywords:
-
secondary full adentia central relation central occlusion orthopedic treatment complete removable plate prosthesis a state of relative calmness of the jaws prosthetic bed
- References:
-
- Azpiazu-Flores FX, Mata-Mata SJ, Lee DJ. Detection of mandibular flexure with a dental plaster verification device: A clinical report with video recording. J Prosthet Dent. 2023 Dec;130(6):807–810. doi: 10.1016/j.prosdent.2022.01.039.
- Bandodkar S, Tripathi S, Chand P, Singh SV, Arya D, Kumar L, et al. A study to evaluate psychological and occlusal parameters in bruxism. J Oral Biol Craniofac Res. 2022 Jan-Feb;12(1):38–41. doi: 10.1016/j.jobcr.2021.10.007.
- Bayramov YI. Functional measurement in orthopedic treatment with full denture. Theoretical & Applied Science. International Scientific Journal. Philadelphia, USA. 2019; 78(10):380–383.
- Bozhkova T, Musurlieva N, Slavchev D. Comparative Study Qualitative and Quantitative Techniques in the Study of Occlusion. Biomed Res Int. 2021 Sep 23; 2021:1163874. doi: 10.1155/2021/1163874.
- Chandra BSP, Ravi J, Arvind P, Apurva Jha, Balendra. A. Biological, technical, esthetic and iatrogenic risk factors for tooth supported fixed partial dentures: A cross sectional study. Journal of cardiac disease research. 2023;14(11):1553–1557.
- Di Berardino F, Filipponi E, Schiappadori M, Forti S, Zanetti D, Cesarani A. The occlusal imaging and analysis system by T-scan III in tinnitus patients. Biomed J. 2016; 39:139e144.
- Ferrato G, Falisi G, Ierardo G, Polimeni A, Di Paolo C. Digital evaluation of occlusal forces: comparison between healthy subjects and TMD patients. Ann Stomatol (Roma). 2017 Nov 8;8(2):79–88. doi: 10.11138/ads/2017.8.2.089.
- Fraile C, Ferreiroa A, Solaberrieta E, Pradíes G. Intraoral versus extraoral digital occlusal records: a pilot study. Int J Comput Dent. 2018;21(4):329–333.
- Kartika K, Mohammadnezhad M, Sivaramakrishnan G, Bhai K, Khan S. The Level of utilization and Satisfaction of Complete Denture Treatment Provided in Fiji from 2010-2016. Global Journal of Health Science. 2022. 14. 43–52. doi: 10.5539/gjhs. v14n1p43.
- Lee W, Kwon HB, Kim MJ, Lim YJ. Determination of the reliability and repeatability of a quantitative occlusal analyzer by using a piezoelectric film sensor: An in vitro study. J Prosthet Dent. 2022 Feb;127(2):331–337. doi: 10.1016/j.prosdent.2020.07.024.
- Li BY, Zhou LJ, Guo SX, Zhang Y, Lu L, Wang MQ. An investigation on the simultaneously recorded occlusion contact and surface electromyographic activity for patients with unilateral temporomandibular disorders pain. J Electromyogr Kinesiol. 2016 Jun; 28:199-207. doi: 10.1016/j.jelekin.2015.11.002.
- Mubaraki MQ, Moaleem MMA, Alzahrani AH, Shariff M, Alqahtani SM, Porwal A, et al. Assessment of Conventionally and Digitally Fabricated Complete Dentures: A Comprehensive Review. Materials (Basel). 2022 May 28;15(11):3868. doi: 10.3390/ma15113868.
- Stupnytsky IR, Rozhko MM, Stupnytskyi RM, Silenko YuI, Yeroshenko HA. Anatomical and topographic features of the structure of the cellular part of the mandible in patients with partial absence of teeth. World of medicine and biology. 2021; 2 (76):142–147. doi: 10.26724/2079-8334-2021-2-76-142-147.
- Wiechens B, Brockmeyer P, Wassmann T, Rödiger M, Wiessner A, Bürgers R. Time of day-dependent deviations in dynamic and static occlusion: A prospective clinical study. J Prosthet Dent. 2024 Jul;132(1):123–131. doi: 10.1016/j.prosdent.2022.05.025.
- Youness A, Merzouk N, Regragui A. Complete Removable Denture Retained by a Symphyseal Single Implant: A Case Report. Cureus. 2024 Feb 26;16(2): e54938. doi: 10.7759/cureus.54938.
- Publication:
-
«World of Medicine and Biology»
Vol. 20 No. 90 (2024)
, с. 20-24
УДК 616.314–089.29–633(075.8)
How to Cite
ANALYSIS OF ACCURACY OF DETERMINING THE CENTRIC RELATION OF JAWS IN SECONDARY COMPLETE ADENTIA. (2024). World of Medicine and Biology, 20(90), 20-24. https://doi.org/10.26724/2079-8334-2024-4-90-20-24
Share

English
Ukrainian